Study and Sizing of Centrifugal Pumps: The Case of SOMAÏR's 2013 Pumps, North Niger

Mahamadou, Ousman and Abdourazakou, Maman Hassan and Harouna, Souley and Souleymane, Illou Issoufa (2024) Study and Sizing of Centrifugal Pumps: The Case of SOMAÏR's 2013 Pumps, North Niger. Asian Journal of Physical and Chemical Sciences, 12 (3). pp. 26-40. ISSN 2456-7779

[thumbnail of Abdourazakou1232024AJOPACS121426.pdf] Text
Abdourazakou1232024AJOPACS121426.pdf - Published Version

Download (610kB)

Abstract

The present study concerns the design and sizing of centrifugal pumps, the case of the 2013 pumps used at the Société des Mines de l'AÏR. The Société des Mines de l'Aïr (Somaïr), characterized by extensive modernization and industrialization, has increasingly new needs. The study began by analyzing the existing situation for each circuit. We then proceeded to size the pumps, choosing the type of pump and the material best suited to each type of circuit, taking into account the characteristics of the fluid being pumped. The suction and discharge head losses are 0.02434 m and 0.038 m respectively. The pump's hydraulic power is 10.806 kW. In view of the 18.5 kW mechanical power required for the drive motor, we have chosen 13.51 kW in order to keep within a reasonable margin. Thus, the pump has an absorbed power of 13.51 kW with an efficiency of 80%. For the P3 2225 pump, the mechanical power is 2.4 kW, the HMT is 50 m, and the flow rate, speed and efficiency are 10 m3 /h, 2900 rpm and 60% respectively. For the P4 5154 pumps in the discharge circuit, the mechanical power of the pump is 6.42 KW, the HMT is 30 m and the flow, speed and efficiency are 50 m3 /h, 2900 rpm and 68% respectively.

Item Type: Article
Subjects: AP Academic Press > Physics and Astronomy
Depositing User: Unnamed user with email support@apacademicpress.com
Date Deposited: 26 Aug 2024 05:09
Last Modified: 26 Aug 2024 05:09
URI: http://info.openarchivespress.com/id/eprint/1950